Cable protection components
Water Blocking Tapes
Contains superabsorbent polymers (SAP) that swell upon contact with water. Their function is to block longitudinal moisture penetration inside the cable. They ensure protection of internal components and stable performance. Applied in HV/MV power, fiber optic, data, telecom, and special cables.
Double Side Non-Conductive Water Blocking TapeSingle Side Non-Conductive Water Blocking TapeDouble Side Semi-Conductive Water Blocking TapeReinforced Non-Conductive Water Blocking TapeReinforced Semi-Conductive Water Blocking TapeFilm Laminated Non-Conductive Water Blocking TapeApplication
Replacement of flooding compound.
General water blocking and bedding for all power cables.
Water blocking reinforcement around cable’s central members.
Longitudinal water blocking of screen area of cables.
Under radial barriers.
Range of products
Non-conductive Water Blocking Tape: single and double layer.
Semi-conductive Water Blocking Tape: single and double layer.
Reinforced Non-conductive Water Blocking Tape.
Reinforced Semi-conductive Water Blocking Tape.
Film Laminated Non-conductive Water Blocking Tape
Key Benefits
Water Blocking Tapes are specialized protective components used in the construction of power, data, and telecommunication cables. They are composed of non-woven or woven substrates impregnated with super-absorbent materials (SAP – Super Absorbent Polymers) that rapidly swell upon contact with water. This swelling effect blocks and seals the cable core or interstices, preventing longitudinal water penetration inside the cable structure.
Key features
- Non-conductive and Semi-conductive performance.
- High water swelling speed for different requirements.
- Low weight. High strength for helical application.
- Thickness from 0.1 mm to 0.3 mm.
- Presented in various forms: Pads, Spools and Jumbo Spools.

Double side non-conductive
water blocking tape
Polyester Non-Woven Top Layer
Polyacrylate Swelling Powder
Corrosion Inhibitor
Polyester Non-Woven Bottom Layer
Replacement of flooding compound. Under radial barriers. Water blocking armouring/ between cable components. Replacement of flooding compound in loose tube constructions. In slotted core designs/water blocking reinforcement layers.
Can be customized as per individual requirements.
| Property | Unit | Specification | Special Tapes | Test Method |
||||||
|---|---|---|---|---|---|---|---|---|---|---|
| ZSD- 20SP65 |
ZSD- 25SP75 |
ZSD- 25A |
ZSD- 30SP90 |
ZSD- 35SP100 |
ZSD- 50SP120 |
ZSD- 20N |
ZSD- 25N |
|||
| Thickness | mm | 0,20 ±0,03 |
0,25 ±0,03 |
0,25 ±0,03 |
0,30 ±0,03 |
0,35 ±0,03 |
0,50 ±0,03 |
0,20 ±0,03 |
0,25 ±0,03 |
ISO 9073-2 |
| Weight | g / m2 | 65±5 | 75±5 | 80±10 | 90±10 | 100±10 | 120±10 | 75±5 | 87±5 | ISO 9073-1 |
| Tensile Strenght | N / cm | ≥25 | ≥40 | ≥40 | ≥45 | ≥45 | ≥50 | ≥30 | ≥35 | ISO 9073-3 |
| Elongation | % | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ISO 9073-3 |
| Swelling Speed | mm / 1’00 | ≥6 | ≥8 | ≥8 | ≥10 | ≥10 | ≥12 | ≥10 | ≥12 | Gili Test 4 |
| Swelling Height | mm / 3’00 | ≥9 | ≥12 | ≥12 | ≥14 | ≥14 | ≥16 | ≥12 | ≥15 | Gili Test 4 |
| Short Term – Long Term Stability |
°C | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | Gili Test 5 |
| Moisture Content | % | ≤6 | ≤6 | ≤6 | ≤6 | ≤6 | ≤6 | ≤6 | ≤6 | ISO 287 |
Roll and spool dimensions
| Slit width (mm) | 10–500 |
| Max. OD (mm) | 400–800 |
| ID (mm) | 76, 102, 152 |
Single side non-conductive
water blocking tape
Polyacrylate Swelling Powder
Corrosion Inhibitor
Polyester Non-Woven Bottom Layer
Replacement of flooding compound. Under radial barriers. Water blocking armouring/ between cable components. Replacement of flooding compound in loose tube constructions. In slotted core designs/water blocking reinforcement layers.
Can be customized as per individual requirements.
| Property | Unit | Special Tapes | Specification | Test Method |
|||||
|---|---|---|---|---|---|---|---|---|---|
| DZSD10 | DZSD 20A-SP56 |
DZSD D18 |
DZSD D20 |
DZSD25 -SP70T |
DZSD25 -N85 |
DZSD30 | |||
| Thickness | mm | 0,10 ±0,05 |
0,22 ±0,05 |
0,18 ±0,05 |
0,20 ±0,03 |
0,23 ±0,05 |
0,25 ±0,05 |
0,30 ±0,03 |
ISO 9073-2 |
| Weight | g / m2 | 40±5 | 56±4 | 60±10 | 70±10 | 75±7 | 85±7 | 90±10 | ISO 9073-1 |
| Tensile Strenght | N / cm | ≥20 | ≥30 | ≥25 | ≥25 | ≥30 | ≥35 | ≥35 | ISO 9073-3 |
| Elongation | % | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ISO 9073-3 |
| Swelling Speed | mm / 1’00 | ≥3 | ≥6 | ≥6 | ≥8 | ≥9 | ≥12 | ≥12 | Gili Test 4 |
| Swelling Height | mm / 3’00 | ≥5 | ≥8 | ≥9 | ≥10 | ≥12 | ≥18 | ≥16 | Gili Test 4 |
| Short Term – Long Term Stability |
°C | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | Gili Test 5 |
| Moisture Content | % | ≤6 | ≤6 | ≤6 | ≤6 | ≤6 | ≤6 | ≤6 | ISO 287 |
Roll and spool dimensions
| Slit width (mm) | 10–500 |
| Max. OD (mm) | 400–800 |
| ID (mm) | 76, 102, 152 |
Double side semi-conductive
water blocking tape
Polyester Non-Woven
Black Carbon
Polyacrylate Superabsorbent Polymers
Replacement of flooding compound. Water blocking armouring/ between cable components of power cable where bedding is required.
Can be customized as per individual requirements.
| Property | Unit | Special Tapes | Specification | Test Method |
||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| BZSD–25 | BZSD–30 | BZSD–30N | BZSD–35 | BZSD–35N | BZSD–40 | BZSD–50 | BZSD–50N | BZSD–60 | BZSD–80 | |||
| Thickness | mm | 0,25±0,03 | 0,30±0,03 | 0,30±0,03 | 0,35±0,03 | 0,35±0,03 | 0,40±0,03 | 0,50±0,03 | 0,50±0,03 | 0,60±0,01 | 0,80±0,05 | ISO 9073-2 |
| Weight | g / m2 | 100±10 | 115±10 | 120±10 | 120±10 | 140±10 | 140±10 | 160±15 | 170±15 | 185±15 | 250±20 | ISO 9073-1 |
| Tensile Strenght | N / cm | ≥25 | ≥40 | ≥40 | ≥40 | ≥40 | ≥40 | ≥50 | ≥50 | ≥120N/ 15mm |
≥40 | ISO 9073-3 |
| Elongation | % | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ISO 9073-3 |
| Surface Resistance | Ω | ≤1500 | ≤1500 | ≤1500 | ≤1500 | ≤1500 | ≤1500 | ≤1500 | ≤1500 | ≤1*10^4 | ≤1500 | Gili Test 8/ DIN53482 |
| Volume Resistance | Ω·cm | ≤1x106 | ≤1x106 | ≤1x106 | ≤1x106 | ≤1x106 | ≤1x106 | ≤1x106 | ≤1x106 | ≤1x106 | ≤5x104 | Gili Test 9/ DIN54345 |
| Swelling Speed | mm / 1’00 | ≥7 | ≥8 | ≥12 | ≥10 | ≥12 | ≥10 | ≥12 | ≥13 | ≥10 | ≥10 | Gili Test 5 |
| Swelling Height | mm / 3’00 | ≥10 | ≥12 | ≥15 | ≥14 | ≥16 | ≥14 | ≥16 | ≥18 | ≥15 | ≥14 | Gili Test 4 |
| Short Term – Long Term Stability |
°C | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | 90–230 | Gili Test 5 |
| Moisture Content | % | ≤9 | ≤9 | ≤9 | ≤9 | ≤9 | ≤7 | ≤7 | ≤7 | ≤7 | ≤7 | ISO 287 |
Roll and spool dimensions
| Slit width (mm) | 10–500 |
| Max. OD (mm) | 400–800 |
| ID (mm) | 76, 102, 152 |
Reinforced non-conductive
water blocking tape
Double Side Reinforced Polyester
Polyester Non-Woven Fabric
Polyacrylate Swelling Powder
Polyester Yarn HT
Replacement flooding compound. Water blocking amouring high strenght between cable components.
Can be customized as per individual requirements.
| Property | Unit | Specification | Test Method | |
|---|---|---|---|---|
| SZSD–30 | SZSD–35 | |||
| Thickness | mm | 0,30 ±0,03 | 0,35 ±0,03 | ISO 9073-2 |
| Weight | g / m2 | 100±10 | 110±10 | ISO 9073-1 |
| Tensile Strenght | N / cm | ≥100 | ≥110 | ISO 9073-3 |
| Elongation | % | ≥16 | ≥16 | ISO 9073-3 |
| Swelling Speed | mm / 1’00 | ≥8 | ≥10 | Gili Test 4 |
| Swelling Height | mm / 3’00 | ≥12 | ≥15 | Gili Test 4 |
| Short Term – Long Term Stability |
°C | 90–230 | 90–230 | Gili Test 5 |
| Moisture Content | % | ≤8 | ≤8 | ISO 287 |
Roll and spool dimensions
| Slit width (mm) | 10–500 |
| Max. OD (mm) | 400–800 |
| ID (mm) | 76, 102, 152 |
Reinforced semi-conductive
water blocking tape
Double Side Reinforced Polyester
Non-Woven Fabric
Polyacrylate Swelling Powder
Polyester Yarn HT
Black Carbon
Replacement flooding compound. Water blocking amouring high strenght between cable components.
Can be customized as per individual requirements.
| Property | Unit | Specification | Test Method | |
|---|---|---|---|---|
| SBZSD-30 | SBZSD-35 | |||
| Thickness | mm | 0,30 ±0,05 | 0,35 ±0,05 | ISO 9073-2 |
| Weight | g / m2 | 100±10 | 110±10 | ISO 9073-2 |
| Tensile Strenght | N / cm | ≥110 | ≥120 | ISO 9073-3 |
| Elongation | % | ≥12 | ≥12 | ISO 9073-3 |
| Surface Resistance | Ω | ≤1500 | ≤1500 | DIN53482 |
| Volume Resistance | Ω·cm | 1x106 | 1x106 | DIN54345 |
| Swelling Speed | mm / 1’00 | ≥8 | ≥10 | Gili Test 4 |
| Swelling Height | mm / 3’00 | ≥12 | ≥14 | Gili Test 4 |
| Short Term – Long Term Stability |
°C | 90–230 | 90–230 | Gili Test 5 |
| Moisture Content | % | ≤8 | ≤8 | ISO 287 |
Roll and spool dimensions
| Slit width (mm) | 10–500 |
| Max. OD (mm) | 400–800 |
| ID (mm) | 76, 102, 152 |
Film laminated non-conductive
water blocking tape
23um and 36um PET Film
Polyacrylate Swelling Powder
Polyester Non-Woven Base Layer
PET Film side contact with jelly to prevent penetration of jelly, guarantee the water blocking tape performance.
Can be customized as per individual requirements.
| Property | Unit | Specification | Test Method | |
|---|---|---|---|---|
| FZSD-23 | FZSD-36 | |||
| Thickness | mm | 0,25 ±0,05 | 0,36 ±0,03 | ISO 9073-2 |
| Weight | g / m2 | 90±10 | 110±10 | ISO 9073-2 |
| Tensile Strenght | N / cm | ≥40 | ≥60 | ISO 9073-3 |
| Elongation | % | ≥12 | ≥12 | ISO 9073-3 |
| Swelling Speed | mm / 1’00 | ≥8 | ≥10 | Gili Test 4 |
| Swelling Height | mm / 3’00 | ≥12 | ≥14 | Gili Test 4 |
| Short Term – Long Term Stability |
°C | 90–230 | 90–230 | Gili Test 5 |
| Moisture Content | % | ≤8 | ≤8 | ISO 287 |
Roll and spool dimensions
| Slit width (mm) | 10–500 |
| Max. OD (mm) | 400–800 |
| ID (mm) | 76, 102, 152 |